High discharge pressure reefer

Web10 de abr. de 2010 · On a recent trip i had this problem. I was on a ship and had a carrier reefer that had a bad smv valve ( would only open 27%). I didn't have a spare on board so I took the valve apart and removed the piston as the manual said. Well while trying to adjust the temp with the suction service valve i encountered the following problem. The … WebHigh discharge pressure . Condenser coil dirty. 7.10. Condenser fan rotating backwards. 7.11. Condenser fan inoperative. 7.11. Refrigerant overcharge or noncondensibles. 7.7.1. Discharge pressure regulator valve defective. 7.21. Discharge service valve partially closed. Open. Suction modulation valve malfunction. 7.19. Low suction pressure

Carrier Supra 760 high pressure code diag and repair procedures

Web86 Check Discharge Pressure Sensor Report alarm at end of day. 87 Check Suction Pressure Sensor Report alarm at end of day. 88 Reserved for CR 89 Check Electronic … Web20 de fev. de 2024 · How to fix error code 10 on TK APU unit. songs of north east england https://vezzanisrl.com

Alarm Codes Thermo King

Web28 de set. de 2024 · Some of these problems are common but require immediate attention. Mentioned below are eight most frequently seen problems in the ship’s refrigeration plant: 1. Compressor Starts But … Web6 de fev. de 2006 · There are many potential causes of high compressor discharge temperatures. A high condensing temperature is one of them. When the condensing … Web*IF YOU ARE IN THE TNT PHASE OF TRAINING DOWNLOAD THE CHECKLIST*http://bit.ly/2PO3aq6In this video I will show you how to fix alarm code … small form factor satcom solutions

Help me with high discharge pressure, I read about and there…

Category:Carrier Refrigeration system R 404A suction pressure and discharge ...

Tags:High discharge pressure reefer

High discharge pressure reefer

How to Troubleshoot Alarm Codes 10 and 20 on a …

Web21 de jan. de 2008 · CTC high discharge I ... Code 10 on SR truck units with open drive scrolls same thing, the high pressure cutout, ... By REEFER-TEK in forum Transport Replies: 0 Last Post: 05-12-2007, 07:25 PM. cooling &freezing comp. By afeef in forum Industrial Compressors WebI get that, but I have 5 reefer like this thermo king and carriers and whn I set 34 it will stay on 34-35 after little time, but this reefer in continuous mode will come to 42 and stay there, …

High discharge pressure reefer

Did you know?

WebAbout Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features Press Copyright Contact us Creators ... Web7.9.2 Replacing High Pressure Switch. 1. Remove the refrigerant charge. 2. Disconnect wiring from defective switch. The high pressure switch is located on the discharge connection or line and is removed by turning counterclockwise. 3. Install a new high pressure switch after verifying switch settings. 4.

Web4 de mar. de 2024 · The refrigeration plants on merchant vessels play a vital part in carrying refrigerated cargo and provisions for the crew on board. In reefer ships, the temperature of the perishable or temperature sensitive …

WebThermo King Alarm Codes - North America. This is a listing of all current truck, trailer, CR, DAS and DSR alarm codes. On multi-temp units, the zone will be identified. Please record all alarms that occur to assist technician in resolving issue. Alarm codes with parenthesis (XX) may exist with alarm code 84 and may clear automatically. WebCarrier Transicold Alarm Codes Defined: 1 LOW LEVEL FUEL. 2 LOW ENGINE OIL LEVEL. 3 LOW COOLANT LEVEL. 11 LOW ENGINE OIL PRESSURE. 12 HIGH COOLANT TEMPERATURE. 13 HIGH DISCHARGE PRESSURE. 15 BATTERY VOLTAGE TOO HIGH. 16 BATTERY VOLTAGE TOO LOW.

WebAssociate Degree. 6,648 satisfied customers. I have a 2004 Thermo SB 190. Shooting codes 13-11-2 6 4 I. I have a 2004 Thermo King SB 190. Shooting codes 13-11-2 6 4 I …

Web00012 High Coolant Temp Unit will restart*, report reactivation. 00013 High Discharge Pressure Unit will restart*, report reactivation. 00014 High A/C Amps Unit will restart*, … small form fit hms manpack setWeb12 de ago. de 2012 · Rheem units need the blade to sit fairly high, and yes, if the blade is not correct, in both rotation, and pitch and depth, and speed, you can indeed get high pressure trip. also the coils could need cleaning. also the compressor itself could be damaged and cause a high pressure trip. the system needs to be checked out by a … songs of o brother where art thouWebUnit was shutting down with a high discharge pressure code. Found a broken wire (signal to Micro) making micro think it had high pressure. Repaired and completed a PM … small form factor vs miniWeb6.12 High Pressure Expansion Valve Malfunction. Condition. Possible Cause. Remedy/Reference Section. High discharge pressure. HPXV coil loose, not fully … songs of olden times wkukWeb13 de abr. de 2015 · The discharge pressures exceeded 330 psi on a continual basis. We removed the refrigerant, re-evacuated to 400 microns and repeated the weighed refrigerant charge. Still massive pressures. I also did this with … songs of orielWeb22 de abr. de 2024 · The objective of any refrigeration system is to collect heat from a low temperature area and move it to a high temperature area. Refrigerant is a substance that acts as a cooling agent by absorbing and giving off heat. Usually there are two types of refrigeration systems commonly encountered : namely the vapor compression cycle … small form factor power supplyWebI have a 2006 Carrier Reefer unit. It has a code a18 (low refrigerant). ... Reefer Help, 2012 carrier reefer, codes are coming out randomly one time low refrigerant pressure , one time is high discharge pressure, other time check refrigeration system. look like reefer leaking ... small form factor printer